国产大鸡巴操美女动漫版,老头老太太操b,久久久久久久久av高清,久久国产精品99国产精

產(chǎn)品詳情
  • 產(chǎn)品名稱:GD1 H2S/CO2有毒激光開(kāi)放式氣體探測(cè)儀

  • 產(chǎn)品型號(hào):
  • 產(chǎn)品廠商:其它品牌
  • 產(chǎn)品文檔:
你添加了1件商品 查看購(gòu)物車
簡(jiǎn)單介紹:
GD1 H2S/CO2有毒激光開(kāi)放式氣體探測(cè)儀 GD1 H2S/CO2有毒激光開(kāi)放式氣體探測(cè)儀,Simtronics GD1設(shè)置有毒氣體檢測(cè)的新標(biāo)準(zhǔn)。使用可調(diào)諧半導(dǎo)體激光器,GD1提供了增強(qiáng)的覆蓋面和糾錯(cuò)的**檢測(cè)。性能提高標(biāo)志著真正一步更改為**系統(tǒng)和生命周期的成本節(jié)約。
詳情介紹:
GD1 H2S/CO2有毒激光開(kāi)放式氣體探測(cè)儀
GD1 H2S/CO2有毒激光開(kāi)放式氣體探測(cè)儀,Simtronics GD1設(shè)置有毒氣體檢測(cè)的新標(biāo)準(zhǔn)。使用可調(diào)諧半導(dǎo)體激光器,GD1提供了增強(qiáng)的覆蓋面和糾錯(cuò)的**檢測(cè)。性能提高標(biāo)志著真正一步更改為**系統(tǒng)和生命周期的成本節(jié)約。


特性:


  • First Exd NIR Laser open path detector for H2S safety related applications
  • 5 years warranty
  • Large area covered with a single unit
  • Sepearate Transmitter and Receiver concept
  • Real cost savings within 2 years
  • Non-consumptive technology
  • Fail safe, with no sleeping affects
  • Suitable for SIL 2 applications
  • No cross interference
  • Low detection levels, suitable for personnel safety
  • Negligible affects from atmospheric changes (fog, etc.)
  • Fastest possible speed of response
  • No zero-point drift, no calibration
  • HART (R) standard

總覽:

The Simtronics GD1 sets a new standard for toxic gas detection. Using a tuneable laser diode, the GD1 delivers enhanced coverage and fail safe detection. The performance improvement marks a genuine step change for safety systems and life cycle cost savings.

The GD1 has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from offshore production facilities to wastewater treatment plants.At the heart of the detector is a tuneable laser diode that eliminates environmental effects from sun, rain and fog. The laser scans single absorption lines where there is no interference from other gases.

Unlike traditional methods for detecting H2S (MOS or EC cell) the GD1 needs no recalibration and can replace multiple standard detectors to cover the same risk. The complete optomechan ical design and construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.

Supplied with worldwide hazardous area approvals. Suitable for use in systems with SIL 2 requirement.

技術(shù)參數(shù):

GENERAL  
Type Gas detector
Product GD1
Product code GD1-L0P-31KH-0XH-A0
Manufacturer Simtronics
   
GAS DETECTOR  
Type Laser Open Path Gas Detector
Design principle Near IR Laser Scanning
IR Source Tuneable laser diode, Laser Class 1, eye safe
Calibrated gas Hydrogen sulphide (H2S)
Detected gases Target gas only
Calibrated range 0 – 200 ppm.m
0 - 500 ppm.m
0 - 1000 ppm.m
0 - 2000 ppm.m
0 - 5000 ppm.m
0- 20000 ppm.m
Path length 5 – 50m; 5 - 75m (long range)
   
PERFORMANCE  
Zero point stability ±2%, Relative to full scale deflection (FS)
Span stability ±3% FS
Response time 5 sec
Tolerable Obscuration ≤98% 
Calibration interval Fixed factory calibrated. No field calibration required.
   
ELECTRICAL  
Power supply 24V DC, (range 18 - 32V DC)
Power consumption 15W max (TX: 10W + Rx: 5W)
Cable entry M20
Heated Optics Yes
Junction box Supplied with Exe junction box for Transmitter (Tx) and Receiver (Rx).
Connection 0.5 mm2 (20 AWG) - 2.5 mm2 (14 AWG), 3 wires
Analogue output signal 0-20mA, max. load impedance 500?.
Fault signalling Diagnosis signalling in the 0.4 - 3.0mA range
Maintenance interface HART v6.0 Universal Commands
   
ENVIRONMENT  
Storage -40°C to +70°C (-40°F to 158°F)
Operation -40°C to +65°C (-4°F to 149°F)
ATEX flameproof -55°C to +75°C (-67°F to 167°F)
Humidity 100% RH (non-condensing)
Ingress IP66 / IP67  DIN 60529
RFI/EMI Complies with EN 61000-6-2, EN 61000-6-4, EN 50270, EN 60945
   
HOUSING  
Ex Classification Tx/Rx: ATEX II 2 G EExd IIC T5 JB: ATEX II 2 G EEx e T6
Material 316 L stainless steel
Weight Tx/Rx: 5.5 Kg (12 lbs),   JB: 2.0 Kg (4.4 lbs)
Dimensions 205L x 115W x 248H (mm),  8.1 x 4.3 x 9.8 (inches)
   
APPROVALS  
ATEX DNV 2008 ATEX 18877X
IECEX DNV 10.0002X
Ingress IP66/IP67 IEC 60529
SIL Suitable for use in SIL2 systems
   
ACCESSORIES  
GD1-X00-TT01 Alignment kit
GD1-X00-TT05 Test cell


文檔:

pdfProduct Sheet H2S398.36 KB

pdfProduct Sheet CO2596.80 KB

pdfOperating Manual (English)2.13 MB

pdfGD1 Drawing240.55 KB

證書:


 

pdfDNV ATEX Certification239.80 KB

pdfDNV IECEx Certification91.57 KB

pdfCE Declaration189.91 KB

pdfSIL 2 Declaration272.91 KB


應(yīng)用:

  • FPSO / FSO / MOPU
  • Marine / Jack Up Rigs
  • Oil & Gas Onshore Drilling Rigs
  • Chemical and Petrochemical Plants
  • Waste Disposal
  • Gas Turbines
  • General Industry